This DTC will set if the output of the ambient air temperature sensor indicates a probable short circuit or an open in the sensor or the associated wiring harness, or a malfunction of the automatic temperature control (ATC) controller.
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Is the resistance measured equal to the specified range at 20-25°C (68-77°F)?  | 2600-2100 Ω  | Go to Step 5  | Go to Step 2  | 
2  | 
 Is there a problem with the wiring or the connector?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Repair the problem found in the ambient air sensor wiring or the connector. Did you complete the repair?  | --  | System OK  | --  | 
4  | Replace the ambient air sensor. Did you complete the replacement?  | --  | System OK  | --  | 
5  | 
 Is the voltage measured greater than or equal to the specified value?  | 4 V  | Go to Step 7  | Go to Step 6  | 
6  | 
 Does this display indicate the continuing presence of a DTC 2 condition?  | --  | Go to Step 8  | System OK  | 
7  | 
 Is the voltage measured less than or equal to the specified value?  | 4 V  | Go to Step 8  | Go to Step 9  | 
8  | Replace the ATC controller. Did you complete the replacement?  | --  | System OK  | --  | 
9  | 
 Did you complete the repair?  | --  | System OK  | --  |